{"id":462,"date":"2009-11-10T09:04:31","date_gmt":"2009-11-10T13:04:31","guid":{"rendered":"http:\/\/www.engineeringradio.us\/blog\/?p=3928"},"modified":"2023-07-09T08:40:24","modified_gmt":"2023-07-09T12:40:24","slug":"transmitter-readings","status":"publish","type":"post","link":"https:\/\/www.engineeringradio.us\/blog\/2009\/11\/transmitter-readings\/","title":{"rendered":"Transmitter readings"},"content":{"rendered":"\n<p>I recently got into an argument about the requirements for transmitter readings with a fellow engineer.&nbsp; Said fellow stated that transmitter readings need to be taken every three hours and that all operators needed to sign on and off the station log.&nbsp; Time was when those things were supposed to be done, that is true.&nbsp; I believe the rules have changed a little bit since he last read them.&nbsp; The current FCC rules (<a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1820.htm\" target=\"_blank\" rel=\"noopener\">part 73.1820<\/a>) state that the following items need to be in the station log:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Tower light malfunctions and repairs<\/li>\n\n\n\n<li>Emergency Alert System (EAS) tests and activations<\/li>\n\n\n\n<li>AM antenna field strength measurements (<a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.61.htm\" target=\"_blank\" rel=\"noopener\">73.61<\/a>) (monitor points)<\/li>\n\n\n\n<li>Calibration of remote control equipment<\/li>\n\n\n\n<li>Equipment performance measurements (frequency, harmonics, spurious emissions, etc) (<a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1590.htm\" target=\"_blank\" rel=\"noopener\">73.1590<\/a>)<\/li>\n\n\n\n<li>Each entry must be signed<\/li>\n\n\n\n<li>The logs are to be reviewed and signed by the chief operator<\/li>\n<\/ol>\n\n\n\n<p>The exception to this is AM stations <em>without<\/em> an FCC-approved antenna sampling system, which indeed require readings on the antenna system every three hours. Most AM stations have an approved antenna sampling system.<\/p>\n\n\n\n<p>If an AM station has an approved sampling system, it will be noted on the instrument of authorization (license).<\/p>\n\n\n\n<p>For transmitter operations, a review of <a rel=\"noopener\" href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1350.htm\" target=\"_blank\">part 73.1350<\/a> shows that the licensees are responsible for ensuring transmitting apparatus complies with all FCC regulations.\u00a0 Specifically:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>73.1350 (b)(2)(c)The licensee must establish monitoring procedures and schedules for the station and the indicating instruments employed must comply with Sec. <a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1215.htm\" target=\"_blank\" rel=\"noopener\">73.1215<\/a>.<\/p>\n<\/blockquote>\n\n\n\n<p>And<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>73.1350 (b)(2)(c)(1) Monitoring procedures and schedules must enable the licensee to determine compliance with Sec. <a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1560.htm\" target=\"_blank\" rel=\"noopener\">73.1560<\/a> regarding operating power and AM station mode of operation, Sec. <a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1570.htm\" target=\"_blank\" rel=\"noopener\">73.1570<\/a> regarding modulation levels, and, where applicable, Sec. <a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.1213.htm\" target=\"_blank\" rel=\"noopener\"> 73.1213<\/a> regarding antenna tower lighting, and Sec. <a href=\"http:\/\/edocket.access.gpo.gov\/cfr_2007\/octqtr\/47cfr73.68.htm\" target=\"_blank\" rel=\"noopener\">73.69<\/a> regarding the parameters of an AM directional antenna system.<\/p>\n<\/blockquote>\n\n\n\n<p>One would assume that would mean some sort of logging. Further, a review of all recent NAL, NOV, and citations from the FCC&#8217;s enforcement bureau shows that field agents investigating a radio station will make their own power measurements if they suspect a broadcast station is operating out of power tolerance. Particularly with AM directional stations that are supposed to reduce power at night. I doubt very much that producing an operating log with in-tolerance power readings would do any good in those circumstances.<\/p>\n\n\n\n<p>For directional AM stations that change power\/mode at night, some routine of checking the transmitter for proper power levels after power\/pattern change needs to be established. If there is an auto logging system, such as a Burk Autopilot, then checking that system for the proper time of day and\/or proper pattern\/power change functioning could take the place of checking the actual transmitter readings as long as there were an alarm (and notification) generated during an out of tolerance condition.<\/p>\n\n\n\n<p>For most FM stations and AM non-directional stations, most modern transmitters have Automatic Power Control (APC) built in. As long as the APC is functioning properly and there is an alarm (with notification) generated when an out-of-tolerance condition occurs (under\/over power), logging power output readings can be done on a weekly maintenance log.<\/p>\n\n\n\n<p>Station logs are to be retained for two years (<a rel=\"noopener\" href=\"http:\/\/edocket.access.gpo.gov\/cfr_2008\/octqtr\/47cfr73.1840.htm\" target=\"_blank\">73.1840<\/a>) and should be available to the FCC for inspection.\u00a0 After two years, throw the logs out because anything that you have on file is liable to be inspected.\u00a0\u00a0 Any rule infractions found in the station logs can lead to an NOV or NAL, even if it happened more than two years ago.<\/p>\n\n\n\n<p>For your reading pleasure:<br>73.1820<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>Sec. 73.1820 Station log.<\/p>\n\n\n\n<p>(a) Entries must be made in the station log either manually by a<br>person designated by the licensee who is in actual charge of the<br>transmitting apparatus, or by automatic devices meeting the requirements of paragraph (b) of this section. Indications of operating parameters that are required to be logged must be logged prior to any adjustment of the equipment. Where adjustments are made to restore parameters to their proper operating values, the corrected indications must be logged and accompanied, if any parameter deviation was beyond a prescribed tolerance, by a notation describing the nature of the corrective action. Indications of all parameters whose values are affected by the modulation of the carrier must be read without modulation. The actual time of observation must be included in each log entry. The following information must be entered:<br>(1) All stations. (i) Entries required by Sec. 17.49 of this<br>chapter concerning any observed or otherwise known extinguishment or improper functioning of a tower light:<br>(A) The nature of such extinguishment or improper functioning.<br>(B) The date and time the extinguishment or improper operation was observed or otherwise noted.<br>(C) The date, time and nature of adjustments, repairs or<br>replacements made.<br>(ii) Any entries not specifically required in this section, but<br>required by the instrument of authorization or elsewhere in this part.<br>(iii) An entry of each test and activation of the Emergency Alert<br>System (EAS) pursuant to the requirement of part 11 of this chapter and the EAS Operating Handbook. Stations may keep EAS data in a special EAS log which shall be maintained at a convenient<br>location; however, this log is considered a part of the station log.<br>(2) Directional AM stations without an FCC-approved antenna sampling system (See Sec. 73.68). (i) An entry at the beginning of operations in each mode of operation, and thereafter at intervals not exceeding 3 hours, of the following (actual readings observed prior to making any adjustments to the equipment and an indication of any corrections to restore parameters to normal operating values):<br>(A) Common point current.<br>(B) When the operating power is determined by the indirect method, the efficiency factor F and either the product of the final amplifier input voltage and current or the calculated antenna input power. See Sec. 73.51(e).<br>(C) Antenna monitor phase or phase deviation indications.<br>(D) Antenna monitor sample currents, current ratios, or ratio<br>deviation indications.<br>(ii) Entries required by Sec. 73.61 performed in accordance with the schedule specified therein.<br>(iii) Entries of the results of calibration of automatic logging<br>devices (see paragraph (b) of this section) or indicating instruments<br>(see Sec. 73.67), whenever performed.<br>(b) Automatic devices accurately calibrated and with appropriate<br>time, date and circuit functions may be utilized to record entries in<br>the station log Provided:<br>(1) The recording devices do not affect the operation of circuits or<br>accuracy of indicating instruments of the equipment being recorded;<br>(2) The recording devices have an accuracy equivalent to the<br>accuracy of the indicating instruments;<br>(3) The calibration is checked against the original indicators as<br>often as necessary to ensure recording accuracy;<br>(4) In the event of failure or malfunctioning of the automatic<br>equipment, the person designated by the licensee as being responsible for the log small make the required entries in the log manually at that time;<br>(5) The indicating equipment conforms to the requirements of Sec. 73.1215 (Indicating instruments&#8211;specifications) except that the scales need not exceed 5 cm (2 inches) in length. Arbitrary scales may not be used.<br>(c) In preparing the station log, original data may be recorded in<br>rough form and later transcribed into the log.<\/p>\n<\/blockquote>\n\n\n\n<p>73.1350:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>Sec. 73.1350 Transmission system operation.<\/p>\n\n\n\n<p>(a) Each licensee is responsible for maintaining and operating its<br>broadcast station in a manner which complies with the technical rules<br>set forth elsewhere in this part and in accordance with the terms of the station authorization.<br>(b) The licensee must designate a chief operator in accordance with Sec. 73.1870. The licensee may designate one or more technically competent persons to adjust the transmitter operating parameters for compliance with the technical rules and the station authorization.<br>(1) Persons so authorized by the licensee may make such adjustments directly at the transmitter site or by using control equipment at an off-site location.<br>(2) The transmitter control personnel must have the capability to<br>turn the transmitter off at all times. If the personnel are at a remote<br>location, the control system must provide this capability continuously<br>or must include an alternate method of acquiring control that can<br>satisfy the requirement of paragraph (e) of this section that operation<br>be terminated within three minutes.<br>(c)The licensee must establish monitoring procedures and schedules for the station and the indicating instruments employed must comply with Sec. 73.1215.<br>(1) Monitoring procedures and schedules must enable the licensee to determine compliance with Sec. 73.1560 regarding operating power and AM station mode of operation, Sec. 73.1570 regarding modulation levels, and, where applicable, Sec. 73.1213 regarding antenna tower lighting, and Sec. 73.69 regarding the parameters of an AM directional antenna system.<br>(2) Monitoring equipment must be periodically calibrated so as to<br>provide reliable indications of transmitter operating parameters with a<br>known degree of accuracy. Errors inherent in monitoring equipment and the calibration procedure must be taken into account when adjusting operating parameters to ensure that the limits imposed by the technical rules and the station authorization are not exceeded.<br>(d) In the event that a broadcast station is operating in a manner<br>that is not in compliance with the applicable technical rules set forth<br>elsewhere in this part or the terms of the station authorization, and<br>the condition is not listed in paragraph (e) or (f) of this section,<br>broadcast operation must be terminated within three hours unless antenna input power is reduced sufficiently to eliminate any excess radiation. Examples of conditions that require termination of operation within three hours include excessive power, excessive modulation or the emission of spurious signals that do not result in harmful interference.<br>(e) If a broadcast station is operating in a manner that poses a<br>threat to life or property or that is likely to significantly disrupt<br>the operation of other stations, immediate corrective action is<br>required. In such cases, operation must be terminated within three<br>minutes unless antenna input power is reduced sufficiently to eliminate any excess radiation. Examples of conditions that require immediate corrective action include the emission of spurious signals that cause harmful interference, any mode of operation not specified by the station license for the pertinent time of day, or operation substantially at variance from the authorized radiation pattern.<br>(f) If a broadcast station is operating in a manner that is not in<br>compliance with one of the following technical rules, operation may<br>continue if the station complies with relevant alternative provisions in<br>the specified rule section.<br>(1) AM directional antenna system tolerances, see Sec. 73.62;<br>(2) AM directional antenna monitoring points, see Sec. 73.158;<br>(3) TV visual waveform, see Sec. 73.691(b);<br>(4) Reduced power operation, see Sec. 73.1560(d);<br>(5) Reduced modulation level, see Sec. 73.1570(a);<br>(6) Emergency antennas, see Sec. 73.1680.<br>(g) The transmission system must be maintained and inspected in<br>accordance with Sec. 73.1580.<br>(h) Whenever a transmission system control point is established at a location other than the main studio or transmitter, a letter of<br>notification of that location must be sent to the FCC in Washington, DC, Attention: Audio Division (radio) or Video Division (television), Media Bureau, within 3 days of the initial use of that point. The letter<br>should include a list of all control points in use, for clarity. This<br>notification is not required if responsible station personnel can be<br>contacted at the transmitter or studio site during hours of operation.<br>(i) The licensee must ensure that the station is operated in<br>compliance with Part 11 of this chapter, the rules governing the<br>Emergency Alert System (EAS).<\/p>\n<\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>I recently got into an argument about the requirements for transmitter readings with a fellow engineer.&nbsp; Said fellow stated that transmitter readings need to be taken every three hours and that all operators needed to sign on and off the station log.&nbsp; Time was when those things were supposed to be done, that is true.&nbsp; &hellip; <a href=\"https:\/\/www.engineeringradio.us\/blog\/2009\/11\/transmitter-readings\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Transmitter readings<\/span><\/a><\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24],"tags":[42],"class_list":["post-462","post","type-post","status-publish","format-standard","hentry","category-fcc","tag-fcc-enforcement"],"_links":{"self":[{"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/posts\/462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/comments?post=462"}],"version-history":[{"count":17,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/posts\/462\/revisions"}],"predecessor-version":[{"id":12098,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/posts\/462\/revisions\/12098"}],"wp:attachment":[{"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/media?parent=462"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/categories?post=462"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineeringradio.us\/blog\/wp-json\/wp\/v2\/tags?post=462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}