Shielded Category Cable

There is some disagreement in the organization that I work with regarding the use of Shielded Cat 5e cable. Is it needed and if so, when and where?  Category cables commonly used in Ethernet computer networks and also used for analog audio and other data applications come in a variety of flavors.  Shielded (Shielded Twisted Pair or STP) and unshielded (Unshielded Twisted Pair or UTP) Cat 5, 5e and 6 are the most common in radio broadcast facilities.

The main purpose for using UTP and STP for high speed data transmission is common-mode rejection.  Cables that are installed in office buildings are subject to various electric and electronic noise sources.  Properly installed UTP works to reject these unwanted signals by using differential signaling, which is balanced.  Differential signaling can best be described as transmitting information using two complimentary signals that are opposite from one and other.

Noise rejection, differential signaling.  "DiffSignaling" by Linear77 - Own work. Licensed under CC BY 3.0 via Wikimedia

Noise rejection, differential signaling. “DiffSignaling” by Linear77 – Own work. Licensed under CC BY 3.0 via Wikimedia

The key performance measurement in category cable is Common Mode rejection.  Outside noise will introduce a common mode signal on the cable which will be cancelled out by the differential amplifier on the receiving end of the circuit.  Proper terminations and good wiring techniques are very important for proper performance.

Using the correct patch panel termination, terminating block or RJ-45 (8P8C) connectors are required to maintain the advertized bandwidth of the cable.  There is also a difference in connector and terminating block designs for solid versus stranded cables.  Using improper connectors for the type of cable installed can cause dropouts and loss of data.

When installing category cable, care must be taken not to kink the cable, not to exceed the recommended minimum bending radius or exceed the maximum pulling force. Each of these will degrade the cable performance by changing the physical characteristics of the cable. Each pair of wires in category cable has a different twist. Altering these twist ratios by stretching the cable or bending it too sharply will increase the NEXT (Near End Cross Talk) and FEXT (far end cross talk) between pairs. In Gigabit networks, this will degrade throughput and create bottlenecks.

Generally speaking, the minimum bending radius is four times the cable diameter, or approximately one inch for Category 6 cable.  The maximum pulling tension is not more than 25 ft/lbs or 110 Newtons.

Category 6, Shielded Twisted Pair

Category 6, Shielded Twisted Pair

In high EMF environments, shielded cable (STP) can be beneficial in mitigating high electrical noise along with proper installations techniques noted above.  Signaling levels on 100BaseT are +1, 0 and -1 volt (MLT-3 Encoding).  On Gigabit Ethernet, the levels are +1, +0.5, 0, −0.5 and −1 Volt (PAM-5 Encoding).  Induced voltages on in cables from external sources can degrade network performance and create bottlenecks.  High EMF environments would include places like transmitter sites and anything on a tower or rooftop.  Properly terminated shielded cable is necessary for EMP protection from lightning strikes or other sources.  STP has special shielded metal connectors which each category cable class.  These connectors supply the path to ground through the RJ-45 jack.

Ungrounded shields are useless.

RJ-45 or 8P8C shielded plug for Category 6 STP

RJ-45 or 8P8C shielded plug for Category 6 STP

There are also other cable characteristics to consider such as UV resistant jacking for outdoor installations or gel filled (AKA “flooded”) cable for wet locations.  Fortunately, there are plenty of sources for these types of cables and they are not terribly expensive.

To answer the question at the beginning of the post; STP can be beneficial at high EMI/EMF or RF sites to mitigate induced voltages on the cable from external sources provided it is properly terminated.  In office and studio locations which are not at or next to a transmitter site, UTP is more than adequate provided it is properly installed and terminated.

Be Sociable, Share!

Comments are closed.

Axiom


A pessimist sees the glass as half empty. An optimist sees the glass as half full. The engineer sees the glass as twice the size it needs to be.

Congress shall make no law respecting an establishment of religion, or prohibiting the free exercise thereof; or abridging the freedom of speech, or of the press; or the right of the people peaceably to assemble, and to petition the Government for a redress of grievances.
~1st amendment to the United States Constitution

Any society that would give up a little liberty to gain a little security will deserve neither and lose both.
~Benjamin Franklin

The individual has always had to struggle to keep from being overwhelmed by the tribe. To be your own man is hard business. If you try it, you will be lonely often, and sometimes frightened. But no price is too high to pay for the privilege of owning yourself.
~Rudyard Kipling

Everyone has the right to freedom of opinion and expression; this right includes the freedom to hold opinions without interference and to seek, receive and impart information and ideas through any media and regardless of frontiers
~Universal Declaration Of Human Rights, Article 19

...radio was discovered, and not invented, and that these frequencies and principles were always in existence long before man was aware of them. Therefore, no one owns them. They are there as free as sunlight, which is a higher frequency form of the same energy.
~Alan Weiner

Free counters!